Breadboard continuity lab
Add jumper wires and components, then use the continuity tester to check whether two points are electrically connected. Hover over (or tap) any hole to light up everything it is connected to. Each component is checked as you place it: a green ✓ means it is placed correctly, a red ✗ explains what is wrong.
Parts tray:
Components on the board
Continuity tester
– – –
Red probe: —
Black probe: —
A multimeter on continuity mode shows ≈0 Ω and beeps when there is a conductive path between the probes, and OL (open loop) when there isn't. Resistors, LEDs, capacitors and pots are not counted as conductors; the pushbutton's permanently joined legs are.
Challenges
Quiz: connected or not?
Press “New question”. Two holes will be marked with ★ — decide whether they are connected without using the probes.
Score: 0 / 0
How a breadboard is wired inside
- Terminal strips: each numbered column of five holes (a–e) is one metal clip, so a1, b1, c1, d1, e1 are all connected. f–j in the same column is a separate clip.
- Centre channel: the gap between e and f is not bridged, so a chip (IC) can straddle it without shorting its pins together.
- Power rails: the long rows along the top and bottom run the length of the board. The top rails are not connected to the bottom rails — add jumpers if you want power on both.
- Split rails: on many full-size boards each rail is broken in the middle (often marked by a gap in the red/blue line). Power applied to the left half does not reach the right half until you add a jumper across the break — a classic reason a circuit on the far side of the board "does nothing". Untick Split power rails to see a continuous-rail board.
- Neighbouring columns (e.g. a1 and a2) are not connected — a common mistake when placing an LED or resistor.
- Placing components: every leg of a component must go into a different strip. Two legs in the same strip are short-circuited, so the current bypasses the component.